BPNMC - JON-DRAW 722X - 16OZ

  • MSDS: BPNMC
  • Manufacturer: CHEM TREND INC
  • Product Name: JON-DRAW 722X - 16OZ
  • National Stock Number: 9150-00N032932
Product Identification

Product ID:JON-DRAW 722X - 16OZ
MSDS Date:01/20/1987
FSC:9150
NIIN:00N032932
MSDS Number: BPNMC

Responsible Party
CHEM-TREND INC
3205 E GRAND RIVER
HOWELL, MI 48843
US

Emergency Phone: 517-546-4520

Info Phone: 517-546-4520

Cage: 2W738

Contractor
CHEM-TREND INC
860 HOWELL, MI 48844-0860 US

Telephone: 800-727-7730

Cage: 2W738

Ingredients

ADDITIVES; (BLEND OF EMULSIFIERS, COUPLERS, WAXES &

Fraction By Weight: 60-70%


PETROLEUM; (PETROLEUM OIL)

CAS: 8007-05-9

RTECS: SE7175000

Fraction By Weight: 30-40%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5MG/M3;10 STEL(MIST)

Hazards

LD50 LC50 Mixture:LD50 (ORAL, RAT):>5.0 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:CONCENTRATE MAY CAUSE
IRRITATION, BUT IS NOT CORROSIVE. DILUTIONS MAY CAUSE SKIN TO DRY
OUT. EYE:CONCENTRATE MAY CAUSE IRRITATION, BUT IS NOT CORROSIVE.
DILUTIONS MAY CAUSE SLIGHT IRRITATION. IN HAL:MISTS OF CONCENTRATE
AND DILUTION MAY CAUSE RESPIRATORY IRRITATION. INGEST:NO ADVERSE
EFFECTS (EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:EXPECTED. DO NOT INGEST. CHRONIC:A
REVIEW OF LITERATURE DOES NOT SHOW OBVIOUS LONG TERM HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:WASH WITH SOAP AND WATER. LAUNDER CONTACTED CLOTHING
BEFORE REUSE. EYES:FLUSH WITH WATER FOR AT LEAST 15 MINUTES.
CONTACT MD. INHAL:IF IRRITATION OCCURS, MOVE TO FRESH AIR.
INGEST:CONTACT MD.

Fire Fighting

Flash Point Method:COC
Flash Point:287F,142C
Extinguishing Media:CONCENTRATE MAY BURN UNDER SEVERE IGNITION
CONDITIONS. USE FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONCENTRATE MAY BURN UNDER SEVERE
IGNITION CONDITIONS. DO NOT CUT OR WELD EMPTY DRUMS UNLESS THEY ARE
THOROUGHLY CLEANED.

Accidental Release

Spill Release Procedures:SMALL SPILLS:SOAK UP WITH ABSORBENT MATERIAL.
LARGE SPILLS:DIKE AREA TO PREVENT RUNOFF, RECOVER LIQUID, SOAKING
REMAINING LIQUID WITH ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP DRUMS AND CONTAINERS OR
CONENTRATE CLOSED WHEN NOT IN USE. ALLOW TO WARM TO ROOM
TEMPERATURES BEFORE DILUTION.
Other Precautions:NONE KNOWN

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD AIR SUPPLIED RESP/AIR
PURIFYING RESP MAY BE USED WHEN ENGINEERING & WORK PRACTICES
CONTROLS ARE NOT TECHNICALLY FEASIBLE, WHEN SUCH CONTROLS ARE IN
PROCESS OF BEING INSTALLED/WHEN TH EY FAIL AND NEED TO BE
SUPPLEMENTED.
Ventilation:LOCAL AND/OR MECHANICAL VENTILATION.
Protective Gloves:OIL IMPERVIOUS GLOVES (VITON/NITRILE)
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APPROPRIATE CLOTHING TO AVOID SKIN CONTACT.
Work Hygienic Practices:GOOD INDUSTRIAL HYGIENE PRACTICES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:<0.1
Spec Gravity:1.04
Evaporation Rate & Reference:<1 (ETHER = 1)
Solubility in Water:NIL
Appearance and Odor:BROWN OPAQUE LIQUID WITH NEUTRAL ODOR.
Percent Volatiles by Volume:1-5

Stability

Stability Indicator/Materials to Avoid:YES
STORE AWAY FROM STRONG OXIDIZERS.
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:HYDROCARBON DECOMPOSITION PRODUCTS AT
ELEVATED TEMPERATURES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.